| UMIS Number | BG-RRP-4.023-2833-C01 |
| Project Name | "Sustainable Energy Renovation of a Multi-family Residential Building for the Owners' Association "Association r.c. Bacho Kiro - Kostinbrod" |
| Beneficiary | 000776363 Kostinbrod Municipality |
| Funding | RRF ==> Recovery and Resilience Plan |
| Date of the Contract/Order | 30.12.2024 |
| Start Date | 30.12.2024 |
| End Date | 30.06.2026 |
| Status of Implementation of the Contract/Order of the Grant | In execution (starting date) |
| Location of Performance |
|
| Brief description |
Проектното предложение включва "Устойчиво енергийно обновяване на Многофамилна жилищна сграда за Сдружение на собствениците "Сдружение ж.к. Бачо Киро" - гр.Костинброд" - с адрес гр.Костинброд, ул.Асен Златарев № 10. Многофамилната жилищна сграда е построена в периода 1970-72г., въведена в експлоатация през 1974г, включва четири етажа със общо РЗП 1223,60 кв.м. Сградата е със един вход като са обособени 12 самостоятелни обекта частна собственост, от които 6 апартамента и 6 гаража. Основните дейности по проекта са: 1.Извършване на обследване за ЕЕ, технически паспорт, и архитектурно заснемане . 2. Организация и управление на проекта и осъществяване на мерките за публичност; 3. Инеженеринг - проектиране, авторски надзор и СМР дейности; 3. Изготвяне на доклад за съответвие и осъществяване на сторителен надзор.; 4. Изготвяне на независима експертна оценка от сертифициран енергиен одитор. Дейностите по проекта включват в себе си следните ЕСМ мерки: - топлинно изолиране на външни стени - предвижда се топлоизолирането на външните стени с топлинна изолационна система с EPS или еквивалентна отговаряща на всички съвременни изисквания за пожарна безопасност. - топлинно изолиране на покрив - В сградата са идентифицирани различни видове типове покриви. Те са без положена топлинна изолация, което води до значителни загуби на топлина.Предвижда се доставката и монтажа на топлоизолация от топлоиз.екструд. пенополистирен XPS или еквивалентна. - топлинно изолиране на под- Основната част от сградата е разположена над неотопляем сутерен. Под остъклените балкони подът е граничещ с външен въздух. Предвижда се доставката и монтажа на топлоизолация от топлоиз.екструд. пенополистирен XPS или еквивалентна по под граничещ с външен въздух, и по по таванската плоча на сутерена. - подмяна на прозорци и врати - старата дървена и PVC дограма на сградата се подменя с нова модерна висококачествена PVC дограма с минимум троен стъклопакет. |
| Activities |
|
| Partners |
|
| Contractors |
|
| Subcontractors | None |
| Members of the Consortium | None |
|
Notes: * The projected contract value may be lower than the reported one because of any of the following reasons:
** This column represents the amount of costs claimed by the beneficiary |
|
| Indicator 1 | Energy-efficiency renovation of residential buildings, Measure Unit: Renovated gross floor area of residential buildings (m2), Base Value: 0.00 , Target amount: 1 223.60 , Reached amount: 0.00 |
| Indicator 2 | Reduced greenhouse emissions, Measure Unit: Tones CO2, Base Value: 0.00 , Target amount: 47.30 , Reached amount: 0.00 |
| Indicator 3 | Reduction of the annual consumption of primary energy kWh/year., Measure Unit: kWh/година, Base Value: 335 735.00 , Target amount: 105 821.00 , Reached amount: 0.00 |
| Indicator 4 | % in primary non-renewable energy consumption, Measure Unit: %, Base Value: 0.00 , Target amount: 68.48 , Reached amount: 0.00 |
| Indicator 5 | Number of renovated housing units, Measure Unit: Number, Base Value: 0.00 , Target amount: 6.00 , Reached amount: 0.00 |
| Total Project cost | 201 175.85 EUR |
| Grant | 201 175.85 EUR |
| Self amount | 0.00 EUR |
| Total actual amounts paid | 0.00 EUR |
| Percentage of EU co-financing | 83.33 % |
| None | |
|
Notes: 1 The quoted value represents the maximum amount of the imposed financial correction. Depending on the performance of the contract, the actual amount of the deducted financial correction may be lower. 2 A financial correction with a zero total value means that it has been canceled as a result of a court judgment. |
|
| Procedure 1 |
Subject to due process: Извършване на обследване за установяване на техническите характеристики на сградата, свързани с изискванията по член 169, ал. 1 (т. 1-5) и ал. 2 от ЗУТ и технически паспорт на сградата, архитектурно заснемане и изготвяне на обследване за енергийна ефективност на сградата;,
Estimated Amount: 3 828.77
|
| Procedure 2 |
Subject to due process: Изготвяне на комплексен доклад за оценка на съответствието на разработените инвестиционни проекти за "Устойчиво енергийно обновяване на Многофамилна жилищна сграда за Сдружение на собствениците "Сдружение ж.к. Бачо Киро" - гр.Костинброд" и осъществяване на независим строителен надзор при реализация на проекта.,
Estimated Amount: 3 227.27
|
| Procedure 3 |
Subject to due process: Изготвяне на независима експертна оценка от сертифициран енергиен одитор след приключване на дейностите по изпълнение на СМР за обект: "Устойчиво енергийно обновяване на Многофамилна жилищна сграда за Сдружение на собствениците "Сдружение ж.к. Бачо Киро" - гр.Костинброд" ,
Estimated Amount: 750.74
|
| Procedure 4 |
Subject to due process: Инженеринг (проектиране, строителство и авторски надзор) на Обект "Устойчиво енергийно обновяване на Многофамилна жилищна сграда за Сдружение на собствениците "Сдружение ж.к. Бачо Киро" - гр.Костинброд"
,
Estimated Amount: 189 619.75
|
Notes:
All amounts are in euro (EUR) / 1 EUR = 1,95583 BGN